Summary
IONM Tech I (minimal qualifications) will become competent in performing testing procedures (SSEP, EMG, EEG, TceMEP, BAER, etc.), including test setup, electrode application, troubleshooting, maintaining patient safety, and other related duties. Strong, well-developed communication skills are essential for this position. Once training is completed and all required institution competencies have been achieved, the Clinical Tech II works under indirect technical supervision. An IONM Tech III is preferred and has Certification in Neurophysiological Intraoperative Monitoring (CNIM). IONM Tech III can perform IONM procedures appropriate to their competence and credentials and has proven competent in the performance of routine single and multi-modality IONM. The Tech III provides findings, results, and a descriptive analysis according to facility policy and procedures.
Job description
Summary of Job Duties
IONM Tech I (minimal qualifications) will become competent in performing testing procedures (SSEP, EMG, EEG, TceMEP, BAER, etc.), including test setup, electrode application, troubleshooting, maintaining patient safety, and other related duties. Strong, well-developed communication skills are essential for this position. Once training is completed and all required institution competencies have been achieved, the Clinical Tech II works under indirect technical supervision. An IONM Tech III is preferred and has Certification in Neurophysiological Intraoperative Monitoring (CNIM). IONM Tech III can perform IONM procedures appropriate to their competence and credentials and has proven competent in the performance of routine single and multi-modality IONM. The Tech III provides findings, results, and a descriptive analysis according to facility policy and procedures.
Responsibilities
- Places electrodes for recording and stimulation according to the International 10-20 System for the requested test.
- Uses settings that correspond to the requested test.
- Uses correct filter settings, stimulation intensities, rates, and sensitivities.
- Performs SSEPs, ABRs, PEEGs, TCeMEPs, and EMGs.
- Performs tests and has a thorough understanding of their corresponding waveforms.
- Proficient in recognizing recorded waveforms and variations from the patient's baseline recording.
- Identifies artifact and eliminates it through changes in settings and/or electrodes.
- Knows about other instrumentation in the OR, how it affects the quality of the neuro-diagnostic recording during surgery, and how other instruments affect the patient's electrical safety.
- Maintains aseptic technique and patient safety by following OR protocol.
- Documents patient data and intra-operative monitoring.
- Reports changes in the patient's condition to appropriate personnel.
- Maintains awareness of activities within the surgical suite.
- Maintains and recognizes whether changes in the patient may be caused by surgical manipulation or changes in anesthetic technique.
- Reports changes due to manipulation or surgical maneuver to surgeon in a timely manner.
- Maintains patient safety by following established protocol for electrical grounding and proper electrode connections.
- Completes and maintains CPR and fire safety certification.
- Properly cleans equipment.
- Uses the correct modalities to elicit appropriate patient responses.
- Uses appropriate tests for the surgical procedure.
- Communicates effectively with surgeons, anesthesiologists, and nurses.
- Applies troubleshooting methods.
- Recognizes and identifies problems, corrects through electrode, settings, or mechanical changes.
- Alerts supervisor to needed repairs or parts.
- May perform other duties as assigned.
Requirements
- High School Diploma plus 5 years of Neurophysiologic Intraoperative experience OR Bachelor's degree plus 1 year of Neurophysiologic Intraoperative experience
- Strong, well-developed communication skills
- CPR and fire safety certification
- Bachelor's Degree in a related field (preferred)
- 3 to 5 years in the neurodiagnostic field (preferred)
- Certification in Intraoperative Neurophysiological Monitoring (CNIM) (preferred)
- Graduate of a CAAHEP-accredited Electroneurodiagnostic (END) program (preferred)
Benefits
- Medical, Dental & Vision
- Holiday, Vacation & Sick Leave
- Education discount
- Retirement up to 10% match
- Basic Life Insurance
- Career Training
- Merchant Discounts
- Concierge prescription delivery
Company overview
The University of Arkansas for Medical Sciences (UAMS) is Arkansas' only comprehensive academic health sciences university and the state's largest public employer. Founded in 1879 by eight physicians, UAMS has evolved into a statewide health system encompassing six colleges: Medicine, Pharmacy, Nursing, Health Professions, Public Health, and Graduate School. As a premier academic medical center, UAMS combines education, research, and clinical care through its UAMS Medical Center, which serves as Arkansas' only adult Level 1 trauma center and the state's sole provider of adult kidney, liver, and pancreas transplants. The institution operates with a $1.3 billion budget and generates over $100 million in annual research funding, maintaining internationally recognized programs in multiple myeloma, aging, and other specialized areas. UAMS supports over 3,000 students, 900 medical residents and fellows, and maintains affiliations with Arkansas Children's Hospital and the Central Arkansas Veterans Healthcare System. With eight regional campuses across Arkansas, UAMS provides extensive community outreach and telehealth services, ensuring healthcare access throughout the state while contributing approximately $3.92 billion annually to Arkansas' economy.